Konica Minolta DD-941 Regiu...
Konica Minolta DD-941 Regius 190 CR System Direct Digitizer W/ Back Up CD~15902
Item specifics
Condition: | Used : |
---|---|
Notes: | “Enjoys Fair cosmetics, No Computer / monitor / Software etc are with the sale , Has konica network error 24000 .....Means network error indicating that there is no communication between the reader and the control station.” |
Model: | 190 | MPN: | DD-941 |
Product details
Manufacturer : | Konica Minolta | |
Item: | Konica Minolta DD-941 Regius 190 CR System Direct Digitizer W/ Back Up CD | |
Model/Cat # |
| DD-941 / Regius 190 |
Serial No. |
| 06760779 |
Made In: | Japan | |
Date of manufacture |
| 2005 |
Short description……………….
Pre-owned items
- 1. Sale is for imaged item only
- 2. Power Consumption AC100/115/120/200/220/230/240V ±10%
50/60Hz approx. 1.1kW
- 3. Last PM info : 10/2017
- 4. There might be scratches here and there due to normal use
FRONT DOOR HAS A CRACK
- 5. No CPU station / Monitor or Software etc
- 6. Utilizing a unique dual bay design,the high speed reader of REGIUS Model 190 processes up to 90 plates per hour for maximum performance. This next generation reader radically improves workflow all within a mere 58×58 cm footprint.
- 7. The "Ultimate Resource Sharing" concept provides the flexibility to separate the location of the consoles and the readers. This allows for the same fast and through image checking as with conventional systems. The result:system layout and productivity are optimized according to the number of examinations conduded, the work line and floor space.
- 8. More details:
https://www.konicaminolta.com/healthcare/products/cr/model190/index.html
- 9. NON STERILE
- 10. Manual: No
- 11. Cleaned : yes
- 12. Extra Parts: No
- Shipping weight: W580×D580×H1230mm/approx. 170kg
Stocks ID: 15902 |
|
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images – Good
- 2. Physical Condition: Please review images before bidding – Fair
- 3. Working Condition: Powers on and following all commands, Has konica network error 24000 .....Means network error indicating that there is no communication between the reader and the control station. .....unable to test in detail-.... being offered AS IS
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.