2008 Toshiba Aplio XG iStyl...
2008 Toshiba Aplio XG iStyle HDD Ultrasound Machine W/ 3 Probes & Manuals~16776
Item specifics
Condition: | Used : |
---|---|
Notes: | “Overall condition seems to be Very good for the console / Comes with 3 X probes , Transducers are offered AS IS / Also has manuals” |
Model: | SSA-790A | Image Dimension: | Two Dimensional |
Product details
Manufacturer : | Toshiba Ultrasound |
Item: | Toshiba Aplio XG Diagnostics Ultrasound Machine Incl. 3 Probes & Manuals |
Model/Cat # | SSA-790A |
Serial No. | 4M30-91190 |
Made In: | Japan |
Date of manufacture | 09-2008 |
Voltage : 120V 12A 60Hz
**Details provided below have been entered to the best of our knowledge. However they still remain prone to minor errors caused while listing**
Feel free to contact us for further information regarding the machine
Short description…
- 1. Sale is for imaged items only.
- 2. Signs of careful use
- 3. Comes with 3 X probes:
-Toshiba PLT-704AT 7.5MHz Linear Array Probe ~15770
DOM : 2009 Serial No.99A0834612
Probe analysis:
Connector has no dents or cracks, No bent pins but may have scratches, ITT DLM-360P connector Lock looks fine Cable may has some stains , HAS A CUT in INSULATION Probe handle and head may have scratches Acoustic lens is smooth
Scan Analysis: Air scan , shadows, Phantom scan weak elements, vascular scan is provided on eBay
-Toshiba PVT-382BT 3.5Mhz Convex Ultrasound Probe ~ 15704
DOM : 2010, Serial No.A5512288
Probe analysis:
Connector has no dents or cracks,No bent pins but may has scratches, ITT DLM-360P connector , Lock looks fine , Cable may have some stains but has no cuts or tears, Probe handle and head may has scratches , Acoustic lens is smooth
Scan Analysis: Air scan shadows,Phantom scan may have weak elements, hepatorenal scan has been uploaded on eBay
-Toshiba PVT-661VT Endocavity Ultrasound Probe ~ 15772
DOM : 2012,
Probe analysis:
Connector has no dents or cracks, No BENT PIN,
No Missing Pins, Has some scratches,ITT DLM-360P connector , Lock looks fine
Cable may has some stain ....No cuts or tears , Probe handle and head may has scratches ...............02 cracks , Acoustic lens is smooth
Scan Analysis: Has Image drop out on air scan and dead elements on Phantom scan. Body scan is not done
ALL PROBES ARE OFFERED in AS IS CONDITION
Image Breakdown is as follows:
*Image 1 = Main image
*Image 2 = Shows the complete preset screen as well as the cosmetics can be seen
*Image 3 = 3 Probes attached to the machine
*Image 4 = Convex Probe Air scan
*Image 5 = Linear Probe Air scan
*Image 6 = Convex Probe, endocavity Air scan
*Image 7 = Convex Probe Body scan, Hepatorenal scan
*Image 8 = Linear Probe Body scan (colored ouput), vascular scan
*Image 9 = Phantom scan for endocavity Probe, Has dead elements
*Image 10= Showing the functionality of printer along with the probes attached
*Image 11= Shows the backside of the machine, highlighting the wheel mounted cart overall
*Image 12= 9X User manuals along with A CD
HDD V5.21 R505
TA 700 LCD Display P/N# BSMB1-8013 S/N# 22705078 DOM# 07-14-2014
Console may have some scratches but no major dents or chips are seen
All probes are offered AS IS, they may have some issues refer to images for output quality
Sony UP 897 Digital Printer (Working) functionality can be seen in the images attached
*Kindly review the images thoroughly and see them with zooming to get complete knowledge about the minute details that we may have overlooked*
We tried our best to showcase the machine in just 12 out of 40+ pictures, still have a query? Feel free to ask us for more images
- 5. Package includes:
Toshiba Aplio XG IStyle HDD LCD Ultrasound Machine
Toshiba PLT-704AT Linear Array Probe
Toshiba PVT-382BT Convex Ultrasound Probe
Toshiba PVT-661VT Endorectal Ultrasound Probe
Sony UP 897 Digital Printer
Operational Manual for Aplio XG SSA-790A (Fundamentals)
Operational Manual for Aplio XG SSA-790A (Measurements Volume)
Operational Manual for Aplio XG SSA-790A (Applications)
Acoustic Power and Surface Temperature Data for Aplio XG SSA-790A
Modification Manual for Models SSA-790A, SSA-680A, SSA-660A
Installation Manual for Aplio XG SSA-790A
Installation Manual for DICOM Advanced Kit USDI-792C
Installation Manual for USDI-790A
Medical Ultrasound Safety Instructional Manual
Toshiba Update Disk for SSA-709A, 680A, 660A
Ground Cable
- Sterilize : No
- Manual : yes
- Cleaned : Yes
- Shipping Weight : 550 pounds
Shipping Ready : No
Stock ID : 16776
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: System is Tested & Perfectly working refer to the images for functionality. all keys are responding , following all commands , no detailed testing can be done due to lack of our knowledge , all probes are offered in AS IS condition, Please read the Transducer analysis provided with each probe...we would recommend to change the endocavity probe due to image drop out. Please exercise your judgment after viewing images. more images can be provided on request .will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.