For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

GE 4C Curved Array Transduc...

GE 4C Curved Array Transducer P/N 2401359 , For Logiq & Vivid Series ~ 16722

Item specifics

Condition:For parts or not working : 
 Notes:SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE / Cable is yellowed
Model:4CMPN:2401359

More details


$232.00

16722

Availability: item available

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

GE

Item:

GE 4C Curved Array Transducer P/N 2401359 , For Logiq & Vivid Series 

Model/Cat #        

4C / 2401359 

Serial No.        

64611WX7

Made In:             

Japan

Date of Manufacture:  

8-2007

Voltage: --

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Parts Only Sale, no refunds, returns or complaints of any sort
  3. 3.   GE 4C Curved Array Transducer P/N 2401359 , For Logiq & Vivid Series 

    

Probe Analysis:


Connector:            No broken or bent pins, may have some scratches & paint loss

Cable:                    Cable is yellowed and has some insulation tear near probe strain relief 

Head & handle:    Seems to be in good shape with no signs of major cracks 

Lock:                     Seems good and firm  

Lens/Membrane:  No cuts, tears or nicks observed


Functionality Analysis:


Air Scan: Deep shadows observed, review functionality images

Phantom Scan: Dead elements observed, review images

Body Scan: Review the Body Scan performed > Review the Hepato-Renal Scan done by placing scan head at Right                      Upper Quadrant> Compare the echo-texture of 2 solid organs. Image dropout & the image produced is of                    poor quality. Color flow looks patchy



     *PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM

   ***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE                                                FUNCTIONALITY OF THE PROBE***

 

    Package includes:-


GE 4C Curved Array Transducer P/N 2401359 , For Logiq & Vivid Series 

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight  : 10 lbs

 

Stock ID : 16722 (R2 C4)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: Parts Only, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Parts Only
  2. 2.    Physical Condition:  Please review images before bidding : Good
  3. 3.    Working Condition: Parts Only..will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.