For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2013 Toshiba PLT-1204BT (18...

2013 Toshiba PLT-1204BT (18L7) Linear Array Ultrasound Transducer Probe ~ 30190

Item specifics

Condition:
Used:
Seller Notes:
“IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY/ Review the functionality images and make an informed decision after examining them closely / May have faint shadows”
Model:
PLT-1204BT
MPN:
PLT-1204BT 

More details


$1,099.20

30190

Availability: This product is no longer in stock.

Product details

Manufacturer

Toshiba

Item:

2013 Toshiba PLT-1204BT (18L7) Linear Array Ultrasound Transducer Probe

Model/Cat #        

PLT-1204BT

Serial No.        

99A1345405

Made In:             

Japan

Date of Manufacture:  

2013-04

Voltage: --

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of average use 
  3. 3.   2013 Toshiba PLT-1204BT (18L7) Linear Array Ultrasound Transducer Probe

     -CE # 0197

    

Probe Analysis:


Connector:            No broken or bent pins, has some scratches

Cable:                    No cuts, tears or leakages observed 

Head & handle:    Has some scratches

Lock:                     Seems to be intact firmly

Lens/Membrane:  Smooth

Frequency:            7-14 Mhz

Applications:         Small Parts, MSK & Vascular


Functionality Analysis:


Air Scan: 2 Shadows observed, shown with pointed finger

Phantom Scan: Has weak elements, review images

Body Scan : Review the Vascular Scan performed of the right Carotid> Observe the lumen> color flow looks VERY                       GOOD, No other parts scanned

 

 

 

     *PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM

   ***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE                                                FUNCTIONALITY OF THE PROBE***


Disclaimer: BEING A RETAILER FOR USED ULTRASOUND PROBES, WE DO NOT GUARANTEE THE COMPATIBILITY OF THE PROBES. IT IS THE BUYER'S RESPONSIBILITY TO CHECK FOR THE COMPATIBILITY OF THEIR SYSTEMS. 

 

    Package includes:-


2013 Toshiba PLT-1204BT (18L7) Linear Array Ultrasound Transducer Probe

 


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight  : 10 lbs

 

Stock ID : 30190 {P.O 4009} (OFHC7)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Good
  2. 2.    Physical Condition:  Please review images before bidding : Good
  3. 3.    Working Condition: Has been tested at our end and the functionality has been shown in the image section, please review the functionality images and make an informed decision....will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)