Biosound ESAOTE LA522E Vascular Linear Array Ultrasound Transducer W/ Case~12945
Item specifics
Condition: | Used : |
---|---|
Seller Notes: | “See images for functionality.......May has weak elements , Has nick at the cable & Handle has minor crakc” |
Brand: | Biosound ESAOTE | MPN: | LA522e |
Model: | LA522e |
Product details
Manufacturer : | ESAOTE /Biosound | |
Item: | ESAOTE LA522E Linear Array ultrasound Probe (variable frequency band) | |
Model/Cat # |
| 9600163000 |
Serial No. |
| 1153 |
Made In: | Holland | |
Date of manufacture |
| NA |
Short description……………….
Pre-owned item:
- 1. Frequency – Frequency: 5.0/7.5 MHz
- 2. Vascular, Pediatric, Small Parts, Contrast Agents Procedures
- 3. Linear array
- 4. Systems: Technos MP, Technos MPX, Technos Partner, Megas CVX, Megas GPX, Caris Plus, MyLab 70, MyLab 50, MyLab 30 CV, MyLab 25, MyLab 20, MyLab 15
Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy
- 5. Transducer analysis:
Connector is good ............No dents or cracks / No broken or bent pins
Cable has some stains ....................cable is yelleowed and has minor nick
Probe handle head has no dents but has cracks near probe starin relief end
Membrane looks smooth
Scan Analysis :
See the monitor images ........Has weak elements , review air scan (Image # 2) Phantom Image (Image # 3) & Vascular images (Right carotid Image # 4, 5)
- 6. Sterilized: NO
- 7. Cleaned : Yes
- 8. Extra Parts: No
9. Case included
10 Shipping weight : 7 lbs
Stocks ID: 12945 / R2C5
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images : Fair
- 2. Physical Condition: Please review images before bidding : Fair
- 3. Working Condition: See the monitor images ........Has weak elements , review air scan (Image # 2) Phantom Image (Image # 3) & Vascular images (Right carotid Image # 4, 5) ..... kindly see the carotid lumen with vascular Blood flow and make up your mind (Being sold As IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Added Comments:
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.