2002 Agilent S12 P/N 21380A...
2002 Agilent S12 P/N 21380A Probe for HP 4500 / 5500 / 7500 /EnVisor (10026 )
Item specifics
Condition: | Used : |
---|---|
Seller Notes: | “Has a lacerated tear in the insulation of the cable” |
Brand: | HP | MPN: | P/N 21380A |
Model: | S12 |
Product details
Manufacturer : | Philips - HP | |
Item: | HP S12 Ultrasound Probe for HP 4500 / 5500 / 7500 /EnVisor | |
Model/Cat # |
| 21380A |
Serial No. |
| US97304123 |
Made In: | USA | |
Date of manufacture |
| 2002 |
Short description……………….
Pre-owned items
- 1. Sale is for the imaged item/s only.
- 2. 5-12 MHz, Phased Array
- 3. Applications: Pediatric Cardiac, Neonatal Cardiac
- 4. Compatible Systems : HP Philips 4500 , HP Philips 5500, HP Philips 7500, HP Philips EnVisor
Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy
- 5. Probe analysis
Connector : no dents cracks or bent pins ......Has scratches
Lock : looks good
Cable : Cable may has some stain and has a lacerated tear in the insulation of the cable
Head and handle : No dents and cracks. lens looks good
Scan Analysis
See the monitor images .......Functional but may has some weak elements
- 6. Manual : No
- 7. Sterilized: No
- 8. Cleaned : yes
- 9. Carrying case : NA
- Extra Parts: No
- Shipping weight : 7 pounds
Stocks ID: 10026 (R3C4) |
|
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images --Good
- 2. Physical Condition: Please review images before bidding – Fair
- 3. Working Condition: Kindly see the monitor images and make up your mind, Rt carotid vascular image has been captured, To give the feel of functionality Right kidney and liver has been imaged......please compare the Hepatic-renal echo texture ..........being a used probe may has slight shadow/s……………We do not comment on the functionality of used probes, please review the images and take your own decision .........(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Added Comments:
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.