GE C364 P/N P9607AB Convex ...
GE C364 P/N P9607AB Convex Array /Curved Ultrasound Transducer Probe ~ 16904
Item specifics
Condition: | Used : |
---|---|
Notes: | “May have some weak elements, you may refer to the images and decide / System is not included in the sale it has only been shown to demonstrate the functionality of the probe /” |
Model: | C364 | MPN: | P9607AB |
Country/Region of Manufacture: | Japan | Brand: | GE |
Product details
Manufacturer : | GE |
Item: | GE C364 Convex Array 2.5 - 5.5 MHz 64mm Ultrasound Transducer Probe
|
Model/Cat # | C364 / P9607AB |
Serial No. | 451056YM6 |
Made In: | Japan |
Date of manufacture | 11-1997 |
Voltage : --
Short description……………….
- 1. Sale is for imaged item only
- 2. GE C364 Convex Array
- Compatible with: GE Logiq 400 and Logiq 500 ultrasound systems
- Applications: abdominal and OB-GYN applications
- Frequency: 3.3/D2.5 MHz
*** Note: Please note that provided info is for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy***
Probe Analysis:
Connector:
Broken Pins: None
Bent Pins: None
Scratches: Yes
Cable:
Cracks: No
Tears: No
Kinking: No
Dirty: No
Head & handle:
Scratches: No
Cracks: No
Lock:
Intact: Yes, Firmly
Missing: No
Lens/Membrane:
Clean: Yes
Nicks: No
Stains: No
Scan Analysis:
Air Scan:
Shadows: Yes, on peripheral right
Image reference: 1-2
Phantom Scan:
Weak Elements: Yes
Dead Elements: No
Image Reference: 3
Body Scan:
Part Being scanned: Hepato Renal & RT Carotid Vascular Scan
Color Flow: Patchy
Image Quality: fair
Image Reference: 4-5
- 4. Package includes:-
GE C364 Convex Array 3.3/D2.5 MHz 64mm Ultrasound Transducer Probe
- Sterilize : No
- Manual : No
- Cleaned : Yes
- Shipping Weight : 8 pounds
Stock ID : 16904 (OFHC7)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: Used
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end, may have some weak elements, you are expected to refer to the images and exercise your judgement ...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.