GE 6.5 Mhz MTZ/P9603MB Endo...
GE 6.5 Mhz MTZ/P9603MB Endocavity Ultrasound Transducer Probe ~ 16940
Item specifics
Condition: | Used : |
---|---|
Notes: | “System is not included in the sale, it has only been shown to demonstrate the functionality / You may refer to the images for functionality ” |
Model: | 6.5 Mhz MTZ | MPN: | P9603MB |
Country/Region of Manufacture: | Japan | Brand: | GE |
Product details
Manufacturer : | GE |
Item: | GE 6.5 Mhz MTZ/P9603MB Endocavity Ultrasound Transducer Probe
|
Model/Cat # | 6.5 Mhz MTZ/P9603MB |
Serial No. | 824461YMB |
Made In: | Japan |
Date of manufacture | 7-2001 |
Voltage : --
Short description……………….
- 1. Sale is for imaged item only
- 2. GE 6.5 Mhz MTZ/P9603MB Endocavity
- Compatible with: Logiq 200 / 200PRO
- Applications: Abdominal,Obsetetrics, Gynecology, Urology
- Frequency: 6.5 Mhz
*** Note: Please note that provided info is for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy***
Probe Analysis:
Connector:
Broken Pins: Yes, refer to the images for configuration
Bent Pins: None
Scratches: No
Cable:
Cracks: No
Tears: No
Kinking: No
Dirty: No
Head & handle:
Scratches: No
Cracks: No, but slight cosmetic gap is noticed
Lock:
Intact: Yes, Firmly
Missing: No
Lens/Membrane:
Clean: Yes
Nicks: No
Stains: No
Scan Analysis:
Air Scan:
Shadows: No
Image reference: 2-3
Phantom Scan:
Weak Elements: None, Smooth image
Dead Elements: None
Image Reference: 2-3
Body Scan:
Part Being scanned: Hepato Renal
Image Quality: Seems nice to us
Image Reference: 4
- 4. Package includes:-
GE 6.5 Mhz MTZ/P9603MB Endocavity Ultrasound Transducer Probe
- Sterilize : No
- Manual : No
- Cleaned : Yes
- Shipping Weight : 8 pounds
Stock ID : 16940 (WH C9)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end, no sign of weak elements or shadows have been observed, produced smooth image...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.