For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

BC Biomedical MAXISIM 2000 ...

BC Biomedical MAXISIM 2000 Patient Simulator W/ Adapter+Case *2018 CALIB* ~19991

Item specifics

Condition:Used : 
Notes:2018 CALIBRATED / In good shape overall / Doesn't come with a module / Comes with its carrying case and power adapter / Please review images and check for compatibility before bidding for the item
Model:

MAXISIM 2000

Brand:

BC Biomedical

More details


$796.00

19991

Availability: item available

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

BioMedical

Item:

BC Biomedical MAXISIM 2000 Patient Simulator W/ Adapter+Case *2018 CALIB*

Model/Cat #        

MAXISIM 2000

Serial No.        

02004

Made In:             

USA

Date of Manufacture:  

U/K

Voltage: --

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of careful use
  3. 3.   Has been tested at our end for Powers On only no detailed inspection could be carried out at our end

      *LAST CALIBRATED ON: 05-July-2018

      *CALIBRATION DUE: 05-JUL-2019

      *In very good shape overall with no signs of cracks, scuffs or scratches of any sort

      *Comes in its carrying case with its power adapter

      

Specifications: (Copied from vendor's website)


*ECG General

Lead Configuration: 12-lead simulation derived from one resistively

divided analog signal.

 RL, RA, LA, LL, V1-6

 Output Impedance

 Limb leads: 500 or 1000 ohms to RL

 V Leads: 1000 ohms to RL

 

 High Level Output: 0.5 V/mV of low level (Lead II) 


Normal Sinus:

 Rates: 30, 60, 80, 120, 180, and 300 BPM

 Rate Accuracy: ± 1% of selection

 Amplitudes: 0.5mV, 1.0mV, 1.5mV and 2.0mV (Lead II)

 Amplitude Accuracy: ± 5%. (Lead II 1.0mV)

 

 Automatic ECG Rate Test


Manual ECG Performance Test:

 Square Wave: 2.0Hz 1.0 V p-p biphasic

 DC pulse: 4.0 sec. 1.0 mV

 Sine Waves: 0.1, 0.5, 10, 40, 50, 60 and 100 Hz

 Triangle Wave: 2.0 Hz

 Amplitude: 0.5mV, 1.0mV, 1.5mV and 2.0mV (Lead II)

 

 Amplitude Accuracy: ± 5%. (Lead II 1.0mV)


Automatic ECG Performance Test:

 Gain/Damping: 2 Hz square wave

 Frequency Response

 Low Frequency: 4 second DC pulse

 Band Pass: 10 Hz sine

 Monitor: -3dB point: 40 Hz sine

 Power Line Notch Filter: 50 Hz sine

 

 Linearity: 2 Hz triangle wave


Blood Pressure General

 Input/Output Impedance: 300 Ohms

 Exciter Voltage Range: 2 to 16 volts

 Exciter Frequency Range: DC to 4000 Hz

 Output Sensitivity: 5 or 40 µV/V/mmHg

 Accuracy: ± 1% full scale ± 1 mmHg

 

 Calibrated Rate: 80 BPM 

 

    Package includes:-


BC Biomedical MAXISIM 2000 Patient Simulator 

MN# 212A2136 Power Adapter

Carrying Case


 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight  : 20 lbs

 

Stock ID : 19991 (WH 666)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Very Good
  2. 2.    Physical Condition:  Please review images before bidding : Very Good
  3. 3.    Working Condition: Has been tested at our end for Powers On only no detailed inspection could be carried out at our end...will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.