BC Biomedical MAXISIM 2000 ...
BC Biomedical MAXISIM 2000 Patient Simulator W/ Adapter+Case *2018 CALIB* ~19991
Item specifics
Condition: | Used : |
---|---|
Notes: | “2018 CALIBRATED / In good shape overall / Doesn't come with a module / Comes with its carrying case and power adapter / Please review images and check for compatibility before bidding for the item” |
Model: | MAXISIM 2000 | Brand: | BC Biomedical |
Product details
Manufacturer | BioMedical |
Item: | BC Biomedical MAXISIM 2000 Patient Simulator W/ Adapter+Case *2018 CALIB* |
Model/Cat # | MAXISIM 2000 |
Serial No. | 02004 |
Made In: | USA |
Date of Manufacture: | U/K |
Voltage: --
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of careful use
- 3. Has been tested at our end for Powers On only no detailed inspection could be carried out at our end
*LAST CALIBRATED ON: 05-July-2018
*CALIBRATION DUE: 05-JUL-2019
*In very good shape overall with no signs of cracks, scuffs or scratches of any sort
*Comes in its carrying case with its power adapter
Specifications: (Copied from vendor's website)
*ECG General
Lead Configuration: 12-lead simulation derived from one resistively
divided analog signal.
RL, RA, LA, LL, V1-6
Output Impedance
Limb leads: 500 or 1000 ohms to RL
V Leads: 1000 ohms to RL
High Level Output: 0.5 V/mV of low level (Lead II)
Normal Sinus:
Rates: 30, 60, 80, 120, 180, and 300 BPM
Rate Accuracy: ± 1% of selection
Amplitudes: 0.5mV, 1.0mV, 1.5mV and 2.0mV (Lead II)
Amplitude Accuracy: ± 5%. (Lead II 1.0mV)
Automatic ECG Rate Test
Manual ECG Performance Test:
Square Wave: 2.0Hz 1.0 V p-p biphasic
DC pulse: 4.0 sec. 1.0 mV
Sine Waves: 0.1, 0.5, 10, 40, 50, 60 and 100 Hz
Triangle Wave: 2.0 Hz
Amplitude: 0.5mV, 1.0mV, 1.5mV and 2.0mV (Lead II)
Amplitude Accuracy: ± 5%. (Lead II 1.0mV)
Automatic ECG Performance Test:
Gain/Damping: 2 Hz square wave
Frequency Response
Low Frequency: 4 second DC pulse
Band Pass: 10 Hz sine
Monitor: -3dB point: 40 Hz sine
Power Line Notch Filter: 50 Hz sine
Linearity: 2 Hz triangle wave
Blood Pressure General
Input/Output Impedance: 300 Ohms
Exciter Voltage Range: 2 to 16 volts
Exciter Frequency Range: DC to 4000 Hz
Output Sensitivity: 5 or 40 µV/V/mmHg
Accuracy: ± 1% full scale ± 1 mmHg
Calibrated Rate: 80 BPM
Package includes:-
BC Biomedical MAXISIM 2000 Patient Simulator
MN# 212A2136 Power Adapter
Carrying Case
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 20 lbs
Stock ID : 19991 (WH 666)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Very Good
- 3. Working Condition: Has been tested at our end for Powers On only no detailed inspection could be carried out at our end...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.