GE 548C Model 2175180 Convex Array Ultrasound Transducer Probe ~ 21176
Item specifics
Condition: | Used : |
---|---|
Notes: | “SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE / Review the functionality images and make an informed decision after examining them closely” |
Model: | 548C | MPN: | 2175180 |
Product details
Manufacturer | GE Healthcare |
Item: | GE 548C Model 2175180 Convex Array Ultrasound Transducer Probe |
Model/Cat # | 548C / 2175180 |
Serial No. | 35211VP2 |
Made In: | Japan |
Date of Manufacture: | 03-1997 |
Voltage: --
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of High use
- 3. GE 548C Model 2175180 Convex Array Ultrasound Transducer Prob
Probe Analysis:
Connector: In good shape with no signs of bent or broken pins observed
Cable: A tear had been observed which has bee taped as shown in the images
Head & handle: Might have a few scratches on it
Lock: Seems good and firm
Lens/Membrane: Has a dent on it and lens seems roughened
Functionality Analysis:
Air Scan: Faint shadows observed, review functionality images
Phantom Scan: May have a few weak elements, review images
Body Scan: Review the Body Scan performed > Review the Hepato-Renal Scan done by placing scan head at Right Upper Quadrant> Compare the echotexture of 2 solid organs. Review the Vascular Scan> performed by placing scan head at Right Carotid >Review the Lumen and Blood flow > Color flow looks patchy
*PLEASE CHECK FOR COMPATIBILITY BEFORE BIDDING FOR THE ITEM
***SYSTEM IS NOT INCLUDED IN THE SALE, IT HAS ONLY BEEN SHOWN TO DEMONSTRATE THE FUNCTIONALITY OF THE PROBE***
Package includes:-
GE 548C Model 2175180 Convex Array Ultrasound Transducer Prob
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 10 lbs
Stock ID : 21176 (WH C3)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Fair
- 2. Physical Condition: Please review images before bidding : Fair
- 3. Working Condition: Has been tested at our end and the functionality has been shown in the image section, has some noticeable weak elements..will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.