For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

Philips V24C Critical Care ...

Philips V24C Critical Care Touch Color Monitor (NBP SpO2 EKG CO CO2 Print) 11046

Item specifics

Condition:Used : 
Seller Notes:NBP, SpO2, EKG , CO, CO2 & Printer modules with NBP ECG SpO2 Cables and Stand
Brand:

Philips

MPN:

M1205A / M1204A

Model:

V24 / 26

More details


$495.96

11046

Availability: This product is no longer in stock.

Product details

Manufacturer :

 

Philips / HP / Agilent Technologies

Item:

 

Agilent Philips V24C Patient Monitor W/ Rack  Six Modules 05 Cables Rolling stand & Sanibasket 

Model/Cat #

 

 M1205A / M1204A

Serial No.

 

See below

Made In:

 

USA / Germany

Date of manufacture

 

2003/08

Short description……………….

Pre-owned items         

SALE is for patient care monitor with accessories

  1. 1.       System includes the following
  2. 2.       Philips P/N M1205-83000 (M1205A/M1204A) monitor, SN 4038A19387, TOUCH SCREEN MONITOR 
  3. 3.       Options : H07 D.0 Standard (ECG NBP SpO2 Temp, Print)   M1012A CO  & M1235A DTM and M1016A CO2  options are installed 

Blood Analysis (M1022A) is not installed 

ADULT / Peadiatics / Neonatal settings 

  1. 4.       Viridia 24/26 Monitor as well as modules may has sticker residue 
  2. 5.       HP M1180A PAN MAX Mobile stand : included 

Size : 48 x 24 inches 

Basket for cables 

Size : 12 x 8 x 6 inches 

  1. 6.   HP Rack pole included 
  2. 7.       HP-Agilent Philips M10141A Module rack,  SN : DE320C7015 DOM 12/2003

MODULES : 

  1. 8.       Agilent HP M1002B ECG/Resp Module 
  2. 9.       Agilent HP M1008B NBP Module 
  3. 10.   Agilent HP M1020A SpO2/Pleth Module 
  4. 11. HP Agilent M1012A CO Module 
  5. 12. HP Agilent M1016A CO2 Module ...........new style (face plate missing) 

13. HP Agilent M1116B  Printer recorder module  

LEADS : 

  1. 14.   NBP Hose (No cuff) .....new 

 

  1. 15.   Spo2 Cable with sensor .....new 
  2. 16.   ECG Cable with patient leads .....new 
  3. 17.   Madison Corp Rack to monitor cable....

       Optional item : SaniBasket for sanitation wipes .......................not included 

  1. 18.   Power cord : included
  2. 19.   Manual : No
  3. 20.   Sterilized: NON-Sterile
  4. 21.   Cleaned : Yes
  5. Shipping weight : 60 pounds

 

Stocks ID:  11046 (WH Bay 1) 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

  1. 1.  Overall Condition:- As seen in images –  Very Good
  2. 2.  Physical Condition:  Please review images before bidding – Good 
  3. 3.  Working Condition:  Powers on , following all commands, SpO2 , EKG and NBP parameters checked, remaining parameters are not tested .....---- offered AS IS
  4. 4.  “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.  Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.  Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Added Comments: 

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.