For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

J&J Syn Titanium CMF Cranio...

J&J Syn Titanium CMF CranioMaxilloFacial/Craniofacial Instrument Set,Case ~30067

Item specifics

Condition:
Used:
Seller Notes:
“Remain untested at our end but appear to be in good functionality / Cosmetically in good shape / Please review images & check for compatibility before bidding for the item”
Model:
447.10
MPN:
447.85 

More details


$1,467.20

30067

Availability: This product is no longer in stock.

Product details

Manufacturer

Synthes

Item:

J&J Synthes Titanium CMF CranioMaxilloFacial/Craniofacial Instrument Set W/ Case

Model/Cat #        

See Below

Serial No.        

N/A

Made In:             

Germany

Date of Manufacture:  

U/K

Voltage: 

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of some use
  3. 3.  Remain untested at our end but appear to be in good functionality

  *CE marked

  *Reusable 

  *Non-Sterile

  *Implant & screws are different, instruments are 90% complete

  *Set comprises of

  *Central Implant Caddy (incomplete)

  *2.0mm Implants

    -6X 447.10 2.0mm TiPlates, 20 holes

    -2X 447.50 2.0mm Ti Oblique Plate

    -447.52 2.0mm Ti Oblique Plate

    -4X 447.85 2.0mm Ti H Plates, 9 holes

    -3X 447.80 2.0mm 2.0mm Ti H Plates, 8 holes

    -2X 447.18 2.0mm Ti Orbital Rim Plates,8 holes

    -13X 447.20 2.0mm Ti Orbital Rim Plates, 10 holes

    -3X 447.22 2.0mm Ti Orbital Rim Plates, 12 holes

    -4X 447.68 2.0mm Ti Double Y Plates

    -447.61 2.0mm Ti Y Plate

    -3X 447.62 2.0mm Ti Y Plates

    -3X 447.81 2.0mm Ti X Plates

  *Missing Cat Numbers are:

    -447.38, 447.51, 447.53, 447.55, 447.54

  *1.5mm Implants:

    -2X 446.18 1.5mm Orbital Rim Plates, 8 holes

    -3X 446.20 1.5mm Orbital Rim Plates, 10 holes

    -3X 446.22 1.5mm Orbital Rim Plates, 12 holes

    -3X 446.10 1.5mm Ti Adaption Plates, 20 holes

    -3X 446.61 1.5mm Ti Y Plates

    -1.5mm Ti Adaption plate, 15 holes

    -347.98 Plate holding forceps

  *Missing cat numbers are:

    -446.44, 446.40, 446.45, 446.53, 446.51, 446.52, 446.50

  *Left sided Drill Bits & screwdriver caddy:

    -2X 314.42 Driver

    -2X 314.43 Driver Sleeve

    -314.46 Driver Sleeve

    -314.00 Driver

    -4X 311.21 2.0mm Taps

    -2X 311.15 1.5mm Taps

    -2X 310.19 2.0mm Drill Bits

    -310.15 1.5mm Drill Bit

    -5X 310.11 1.1mm Drill Bit

    -Walter Lorenz 01-0265 Bone Screw

  *Caste Instruments:

    -319.51 Depth Gauge

    -2X 311.01 Screw Drivers

    -322.15 2.0/1.5mm Drill Guide, DBL Ended

    -314.14 1.5/1.5mm Drill Gide, DBL Ended

    -2X 347.90 Universal Pliers

    -2X 347.94 Bending Pliers

    -391.96 Cutter

  *Missing:

    -319.39 Sharp Hook

    -312.22 Double Drill Sleeve

    -398.77 & 398.78 Screw Holding forceps

  *Right Sided Screw Case:

    -9X 419.51 2.4mm Emergency Screws, 6mm

    -9X 419.52 2.4mm Emergency Screws, 8mm

    -9X 419.52 2.0mm Emergency Screws, 8mm

    -24X 401.78 2.0mm Caster Screws, 8mm

    -28X 401.76 2.0mm Caster Screws, 6mm

    -26X 401.74 1.5mm Cortex Screws, 8.0mm

    -19X 400.78 1.5mm Cortex Screws, 6mm

    -10X 400.74 1.5mm Cortex Screws, 4mm 

  *Missing cat numbers are:

    -400.80, 400.82, 400.84, 400.88, 401.80, 401.82, 401.84, 401.86, 401.88

  *Lock on PEG one side of the case is missing - Last images 21 / 22

  *Please review images & check for compatibility before bidding for the item

 

    Package includes:-


J&J Syn Titanium CMF CranioMaxilloFacial/Craniofacial Instrument Set 

Case


 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight : 30 lbs

 

Stock ID : 30067 (P.O 4008) (R3C13)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Very Good
  2. 2.    Physical Condition:  Please review images before bidding : Very Good
  3. 3.    Working Condition: Remain untested at our end but appear to be in good functionality...will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)