For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

Gambro Datex ENGSTROM Erica...

Gambro Datex ENGSTROM Erica IV ICU Ventilator / Monitor ~ 13217

Item specifics

Condition:Used : 
Notes:Signs of usage
Brand:

Gambro Datex

MPN:

Erica IV

Model:

ENGSTROM

More details

On sale On sale!
$52.00

13217

Availability: This product is no longer in stock.

Product details

Vendor

 

Gambro Datex ENGSTROM  

Item

 

Erica IV ICU Ventilator

Model/Cat#

 

Erica IV

Serial #

 

1003302

Voltage

 

120V, 60Hz, 50VA

Made In:

 

Sweden

 

 

 

Date of manufacture

 

NA

 

Short description……………….

 

Pre-owned items

 

Some scratches on Top

02 hoses are attached on the back

No manual

No accessories

 

Shipping charges are high as it’s a heavy item (80 pounds)

Medical Gas pressures:

Air 340-981 kPa

O2 290-580kPa

 

Manufacturer Specifications

  

 

MODEL

ERICA ICU Ventilator

IMV/SIMV

Yes

Pressure support (Simv)

Yes

Other (ROTORS)

EMMV backup mode

ELECTRICAL POWER

 

Voltage, AC (ELECTRICAL POWER)

100/110/120/220/240

POWER CONSUMPTION, W (OTHER AVAILABLE ROTORS)

70VA

DIMENSIONS (HXWXD) CM,(IN) (ALERTS)

46x 47 x 31 (18.1x 18.5 x 12.2) without stand

WEIGHT, kg (lb) (DISPLAY)

32(70.6)

REGULATORS

 

Tidal volume, ml (CONTROLS)

100-2,000

Insp flow, l/min (REGULATORS)

20

Insp pres, cm H2O (REGULATORS)

120 (maximum)

Normal breathing rate, BPM (REGULATORS)

1-60

Insp time, sec (CONTROLS)

Indirectly set

Exp time, sec (REGULATORS)

Indirectly set

I:e ratio (REGULATORS)

1:3 to 3:1

FiO2, percent (I:E ratio)

21-100

Sigh volume, mL (CONTROLS)

1.5x TV

Sigh rate (CONTROLS)

1/100 breaths

Auto sigh breath (REGULATORS)

Yes

Peep/cpap, cm h2o (REGULATORS)

0-30

Nebulizer (REGULATORS)

Yes

Sensitivity (DETECTOR)

0-0.2 L/s

Other (ROTORS)

Insp pres assist (0-20 cm H2O)

INTERFACING

 

Output ports (INTERFACING)

Yes

ANALOG OUTPUT (CONFIGURATION)

Yes

Hard copy (Report generation)

Yes

PNEUMATIC POWER (Volume)

 

Compressor

Yes

Pressure ranges (EQUIPMENT ALARMS)

340-980 kPa

EQUIPMENT-RELATED ALARMS

 

Gas supply malfunction (ALERTS)

Yes

Power loss (ALERTS)

Yes

PHYSIOLOGIC MONITORS

 

Pressure displayed (PHYSIOLOGIC MONITORS)

Yes

Alarm(s) (Pressure)

Yes

Volume displayed (PHYSIOLOGIC MONITORS)

Yes

Alarm(s) (Pressure)

Yes

FiO2 displayed (PHYSIOLOGIC MONITORS)

Yes

Alarm(s) (Pressure)

Yes

Respir mechanics displayed (PHYSIOLOGIC MONITORS)

Lung mechanics

Alarm(s) (Pressure)

Yes

Other (ROTORS)

Spontaneous activity

DISPLAYS (STAINING POSTS)

LED

DATA DISPLAYED (REGULATORS)

Numbers, trends

MODES OF OPERATION

 

Assist (MODES OF OPERATION)

Yes

Control (TEMPERATURE)

Yes

Assist/control

Yes

  

 

 

 

Shipping Weight : 80 pounds 

 

Stocks ID: 2646 (13217 ~ new / SC6)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

Overall Condition:  Good /As is

Physical Condition:  - Kindly see all images before bidding!

Working Condition:  Powers on, Not tested technically or professionally at our end --- being sold STRICTLY AS IS! 

Biomed check is strongly recommended before use

Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)

Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

 

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.