Stryker 279-000-000 SERFAS ...
Stryker 279-000-000 SERFAS Energy RF Generator W/O Accessories (10643)
Item specifics
Condition: | Used : |
---|---|
Seller Notes: | “Enjoys good cosmetics” |
Brand: | Stryker | MPN: | 279-000-000 |
Model: | 279-000-000 |
Product details
Vendor: | Stryker instruments crop | |
Item: | SERFAS Energy Ref 279-000-000 RF Generator /Ablation System | |
Model/Cat # |
| 279-000-000 |
Serial No. |
| 05I013914 |
Made In: | USA | |
Date of manufacture |
| NA |
Short description……………….
Pre-owned items
- 1. Voltage : 100-120/ 220-240V, 50/60HZ, 7/4A
- 2. Output power 400W 200ohms
- 3. Operating frequency : 200KHz
- 4. Back panel has hand control and sidne inlet volume control and AC supply inlet
- 5. No probes with the items, power cord included
- 6. Sterilized: No
- 7. Manual: No
- 8. Extra Parts: No
279-000-010 (Footswitch) is not included
Stocks ID: 10643 (WHC2)
BRIEF INFO : Copied from manufacturer website
Stryker’s RF Ablation System offers a variety of procedural specific probes. The bipolar function of the Energy probes eliminates the need for a grounding pad.
Features & Benefits
- Hand control
All SERFAS Energy probes come with a hand control option, allowing the surgeon to control ablation, coagulation and power settings directly from the hand piece. - Bendable probes
Non-suction probes can be bent up to 45 degrees with the probe bender. - A small, powerful generator
The SERFAS Energy generator, while small in size, outputs 400 watts, as much or more power than any other generator on the market. - Eleven distinct power levels
The eleven power levels are the most currently offered by any system on the market. This feature gives the surgeon the ability to fine tune the ablation intensity and performance. - Impedance detection technology
Special impedance detection technology ensures that probes will not damage nearby scopes. - RFID technology
The system communicates specific default and maximum power settings of each probe to the SERFAS Energy console. - Integrated Cable
All probes come with an integrated cable and are fully disposable, so there is no need to re-sterilize cables after a case.
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images – Good
- 2. Physical Condition: Please review images before bidding : Good
3. Working Condition: Powers on , and responding to the commands at touch pads, --“As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 4. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.) no other accessories
Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Added Comments:
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.