GE Marquette Clab II Plus 3...
GE Marquette Clab II Plus 32 Amplifier W/ Catheter Input Module & Parts~ 24302
Item specifics
Product details
Manufacturer | GE Healthcare |
Item: | GE Marquette Clab II Plus 32 Amplifier W/ Catheter Input Module, Filter Box, Fiber Optic Cable, Stim & Aux Cable |
Model/Cat # | Cardiolab II Plus 32 / 2003434-001 / 301-00205-08 / 30100204-03 / 301-00207-03 / 2003410-001 / 301-00202-008 / 2004965-00 / |
Serial No. | See Below |
Made In: | USA |
Date of Manufacture: | U/K |
Voltage: --
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of careful use
- 3. Has been tested at our end for Powers On, unit follows commands therefore seems functional to us
*Detailed inspection could not be performed at our end due to the complexity of the unit
*The unit is SHIPPING READY
*System comprises of:
GE Marquette Clab II Plus Amplifier:
-Has been tested at our end & is in good functionality
-100-240V 0.5A-0.25A 50-60Hz
-Unit powers on> Data LED lights up > No Error Reported therefore seems functional to us
-Has ports for CIM, Aux, Stim, ECG & Press
GE Ref 2003434-001 Fiber Optic ST to FDDI Cable:
-75 ft long
-New & never used
-No sign of cuts, tears or leakages observed
-Price for new from manufacturer $395
GE 301-00204-08 CLab II Plus Cable:
-Auxiliary Input
-8 ft long
-New & never used therefore in excellent cosmetics
-No sign of cuts, tears or leakages observed
-RF Recorder Cable
GE 301-00204-03 Stim Cable:
-Has been owned previously & shows some signs of usage on it, might also be a little dirty
-No sign of cuts, tears or leakages observed
GE 301-00207-03 Stimulator Extender Cable:
-Class II
-Never used therefore in excellent shape
-3-ft long
-No sign of cuts, tears or leakages observed
GE 2003419-001 ECG Cable Series 10K Trunk Cable:
-Comes with its leads
-Cosmetically in very good shape
-No signs of cuts, tears or leakages observed
GE 301-00202-008 Catheter Input Module W/ Cable:
-Lot # 011208G
-Has been tested at our end & functionality has been shown in the image section
-Powers On when connected to the unit
-No cuts, tears or leakages observed
GE P/N 2004965-00 Pacing Enabled RF Filter Box:
-In good shape overall
*Please review images and check for compatibility before bidding for the item
Package includes:-
GE Marquette Clab II Plus Amplifier (S.N: MIXJ08421)
GE Ref 2003434-001 Fiber Optic ST to FDDI Cable
GE 301-00204-08 CLab II Plus Cable
GE 301-00204-03 Stim Cable
GE 301-00207-03 Stimulator Extender Cable
GE 2003419-001 ECG Cable Series 10K Trunk Cable
GE 301-00202-008 Catheter Input Module W/ Cable
GE P/N 2004965-00 Pacing Enabled RF Filter Box
Power Cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 30 lbs
Stock ID : 24302 {P.O 2002} (WH 104-2)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Very Good
- 3. Working Condition: Has been tested at our end for Powers On, unit follows commands therefore seems functional to us...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.