For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2015 Instrumentation Lab AC...

2015 Instrumentation Lab ACL TOP 300 CTS Coagulation Analyzer W/ Supplies ~31324

Item specifics

Condition
Used
Seller Notes
“Has been tested at our end & is in good functionality / Cosmetically in good shape / UNIT IS PASSWORD PROTECTED & WE DO NOT HAVE THE PASSWORD/ Please review images”
Model
ACLTOP 300
MPN
00000280060

More details


$2,754.40

31324

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Instrumentation Lab

Item:

2015 Instrumentation Lab ACL TOP 300 CTS Coagulation Analyzer W/ Supplies

Model/Cat #        

ACL TOP 300 CTS

Serial No.        

See Below

Made In:             

USA

Date of Manufacture:  

U/K

Voltage: --

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of some use 
  3. 3.   Has been tested at our end & is in good functionality as shown in the images

  *UNIT IS PASSWORD PROTECTED & WE DO NOT HAVE THE PASSWORD 

  *Workstation has:

   -Windows XP 2002 SP 3

   -Intercore Duo CPU P8400@ 2.26 Ghz 5.31 Ghz, 

   -1.93 GB RAM

  *CE marked

  *Cosmetically in very good shape with no dents or cracks observed

  *May have a few scratches on it

  *Glass shield is intact

  *RECOMMENDED TO HAVE P.M BEFORE CLINICAL USE, NOT LABELLED AS PATIENT READY

  *Touchscreen is responsive

  *Comes with various accessories 

  *Additional Info:

      The ACL TOP 300 CTS Coagulation analyzer, by Instrumentation Laboratory. Coagulation analysis detects abnormalities in the components required to complete normal blood clotting. Analysis is divided into two elements; the measurement of clot timing and if the timing is abnormal, a deeper analysis to determine which factors affecting normal coagulation are deficient. Clotting disorders are either classified as Hypocoagulability, a disorder of impaired or slowed coagulation and Hypercoagulability, a disorder of unnaturally fast clotting time or manner. Hypocoagulability can result in hemorrhage or other acquired coagulation disorders such as Hemophilia while Hypercoagulability can cause unnatural clots in arteries and other vessels which could result in severe organ damage or possibly death. A balance normally exists between the factors that stimulate formation of thrombin and forces acting to delay thrombin formation. This balance maintains circulating blood as a fluid. When injury occurs or blood is removed from a blood vessel, this balance is upset and coagulation begins. Coagulation may occur unexpectedly and internally. Symptoms for coagulation disorders are spontaneous bruising, prolonged bleeding, abnormal nosebleeds, heavy menstrual flow or gastrointestinal bleeding.

  *Please review images and check for compatibility before bidding for the item

 

    Package includes:-


Instrumentation Laboratory ACL TOP 300 CTS Analyzer 

Instrumentation Lab P/N 28622934 CPU Workstation 

Keytronic E06101U1 Keyboard (S.N: C134800145)

Keytronic USB Based Mouse (S.N: 1419010084)

Honeywell Model 1900 Bar Code Scanner

EDAC Power Elect Adapter

2X Hospital Grade Power Cords

3X Ethernet Based Interface Cables

RS232 Interface Cables  (AM Pro to CM)

ACL TOP Printer Driver CD

ACL TOP System Software Version 5.1.0 Date 06-09-2015

2X ACL TOP Test Definition Library Version P-16.3 (Date 6-9-2015)

ACL TOP Drivers & User Manual CD

Touchpen

282104 Mount & C-Clamp

P/N 000148711 Fuse 8A 250V (Qty 5)

P/N 00014871708 Fuse 4A 250V (Qty 5)

P/N 00014871713 Fuse 2.5A 250V (Qty 5)

P/N 00014971709 Fuse 5A 250V (Qty 5)

P/N 00014871705 Fuse 2A 250V (Qty 5)

P/N 00014871713 Fuse 10A 250V (Qty 3)

2X Screws

P/N 00028386300 Filter Changer

P/N 00028533600 Sample Tube Adapter 10/PK ACL 500-CTS

P/N 00018924104 Bottle Kit, (10X 4ML, Qty 10)

P/N 0019085463 Vial Glass (Qty 5)

P/N 00018902000 Bottle Plastic 30ML (Qty 9)

9X Tubes (No P/N) 

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight : 300 lbs

 

Stock ID : 31324 (P.O 4007) (Loc wh104)

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Vert Good
  2. 2.    Physical Condition:  Please review images before bidding : Very Good
  3. 3.    Working Condition: Has been tested at our end for Powers On, no detailed inspection could be performed at our end...will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)