Integra CUSA Excel Ultrason...
Integra CUSA Excel Ultrasonic Surgical Aspiration Console W/ Foot Pedal ~ 33425
Item specifics
Product details
Manufacturer | Integra Lifescience |
Item: | Valley Lab Integra CUSA Excel Ultrasonic Surgical Aspiration Console W/ Foot Pedal |
Model/Cat # | CUSA Excel |
Serial No. | U2J1354S |
Made In: | USA |
Date of Manufacture: | 2002-10 |
Voltage: 95-120V 50-60Hz 1200VA
Short description...
- 1. Sale is for imaged items only.
- 2. Signs of average use
- 3. Has been tested at our end for Powers On, no detailed inspection could be performed
*Unit Powers on> Displays lights > wait indicator lights up
*CE # 0086
*Last PM: Info N/A
*Output frequency: 23/36Khz
*Int: 10min/5min
*No vibration, foot control or cooling water alert noted at start up
*Cooling water reservoir is NOT INSTALLED
*Has handpieces alert> Handpiece not connected as no handpiece included with the unit
*I/V pole is intact & adjustable
*Console LED control box is height adjustable & can be moved up & down
*No disposable cannisters
*Contamination guard Ref C0005 is NOT INCLUDED
*No disposables, handpieces, suction cannister or tools included with sale
*Fluid pump has some scratches & scuffs maybe
*Has 4 lockable wheels, caster base
*Please review images & check for compatibility before bidding for the item
Package includes:-
Integra Lifesciences CUSA Excel Ultrasonic Surgical Aspiration Console
Valleylab 150-000-090 Foot Pedals Lot # 525468
Power cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
- 6. Sterilized : No
- 7. Manual : No
- 8. Cleaned : Yes
- 9. Shipping Weight : 350 lbs
Stock ID : 33425 (P.O 2012) (WH 000)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end for Powers On, unit follows commands therefore seems to be in good functionality.......will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)