PHARMACIA BIOTECH UV-MII Control & CONDUCTIVITY MONITOR (2120 )
Item specifics
Condition: | Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully ... Read more | Brand: | PHARMACIA |
MPN: | BIOTECH UV-MII | Model: | BIOTECH UV-MII |
Product details
Manufacturer: PHARMACIA BIOTECH
Control unit:
Model: UV-MII Ref/Sys #: 18-1001-10
Serial # 66101433
Voltage:100/120/220-230/240, 50-60hz, 15W
Conductivity Monitor:
Ref/Code#:18-1500-00 System#:18150000
Serial#:56150000 H5 003998
Voltage: 100-240V, 50-60Hz, 15W
Model Years: NA
Made in Sweden Mfg date: NA
Stocks ID: 2120
Description:
PHARMACIA BIOTECH UV-MII 18-1001-10 Control unit AND 18-1500-00 CONDUCTIVITY MONITOR
The UV-M ll Optical Unit houses the lamp (Hg or Zn), the wave length filter and the flow cell. The light beam is directed through a conical or straight flow-through cuvette (6 µl or 2 µl illuminated volume), to a photo detector. The photo detector current is passed to the signal processing circuitry in the control unit.
SPECIFICATIONS
Sensitivity range: 1 microS / cm -999.9 mS / cm
• Noise: + / -0.5% full scale calibrated range
• Internal volume: 14 microLiter
• Flow rate range: 0 - 100 mL / min
• Maximum operating pressure: 50 bar
Both items were tested and appear to be in working
Comments:
It is a used item and expects some minor wear and tear.
System includes control unit, conductivity monitor, 02 power cables and 01 recorder cable only.
Optional Accessories: - none
Concern or query: Ask a Question
Condition:
Overall Condition: Good (The conductivity detector did go through calibration and self-testing, and both said ok with no errors ( please refer to pictures ).
Cosmetics: Very Good (look at all pictures before bidding.)
Functionality: Used item/Very good/Being sold AS IS
Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
Available Documentation (manual etc.): None
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.