2006 Siemens Acuson Antares...
2006 Siemens Acuson Antares PH4-1 P/N 7466910 Ultrasound Transducer Probe ~15861
Item specifics
Condition: | Used : |
---|---|
Notes: | “Review Images for cosmetics and Functionality ,Take a look on Air scan Phantom scan & Solid organ / Vascular Scans / May have weak elements” |
Model: | PH4-1 | Brand: | Acuson |
MPN: | 7466910 |
Product details
Manufacturer : | Siemens Medical Solutions | |
Item: | Siemens Antares PH4-1 Transducer ultrasound probe | |
Model/Cat # |
| 07466910 / PH4-1 |
Serial No. |
| 54941313 |
Made In: | Korea | |
Date of manufacture |
| 2006 |
Short description……………….
Pre-owned items
- 1. Sale is for the imaged item/s only.
- 2. Features:
• Hanafy lens transducer technology
• User selectable MultiHertz imaging
• Lightweight transducer with flexible cable
- Frequency Bandwidth: 4 – 1 MHz
- Selectable 2D Frequencies: 4.00, 3.08, 2.67, 2.22, 1.82 MHz
- Selectable THI Frequencies: 2.22, 2.00, 1.82, 1.67, 1.54 MHz
- Selectable Color Doppler Frequencies: 3.3, 2.7, 2.0 MHz
- Selectable Doppler Frequencies: 3.3, 2.7, 2.0 MHz
- 3. Applications:
- 4. Compatible with SIEMENS ACUSON SONOLINE ANTARES
- 5. Probe analysis:
Adult Abdomen, OB/GYN, Fetal Echo, Pelvis, Renal
Connector : No dents cuts tear or bent pins,
ITT Cannon DLMG 360-P
Lock looks good
Cable has a small tear in the insulation
Head and handle : no bent crack in the Handle , membrane looks fine
Scan Analysis :
Review Air Scan Image # 1, 2 Phantom Scan Image # 3 & Vascular Scan (Right carotid Lumen - Blood flow, Hepatorenal scan ) Images # 4, 5, 6 Unit may have few weak elements
- 6. Manual : No
- 7. Sterilized: No
- 8. Cleaned : yes
- 9. Carrying case : NA
- Extra Parts: No
- Shipping weight : 7 pounds
Stocks ID: 15861 ~ WHC10 |
|
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: .... Review Air Scan Image # 1, 2 Phantom Scan Image # 3 & Vascular Scan (Right carotid Lumen - Blood flow, Hepatorenal scan ) Images # 4, 5, 6 Unit may have few weak elements ...(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.