2008 TOSHIBA PLT-604AT LINE...
2008 TOSHIBA PLT-604AT LINEAR ARRAY PROBE (TOSHIBA APLIO & XARIO SERIES) ~15766
Item specifics
Condition: | Used : |
---|---|
Notes: | “See Images for cosmetics / Untested at our end as we do not have a console / reported to have few weak elements” |
Model: | PLT-604AT | MPN: | PLT-604AT |
Modified Item: | No | Brand: | Toshiba |
Product details
Manufacturer : | Toshiba Medical System Inc. | |
Item: | Toshiba PLT-604AT Linear Array Ultrasound Probe for Aplio & Xario Series | |
Model/Cat # |
| PLT-604AT |
Serial No. |
| 99A0874526 |
Made In: | Japan | |
Date of manufacture |
| NA |
Short description……………….
Pre-owned item:
1. Features :
- 38mm probe
- Vascular use
- Frequency Range: 4.0 to 10.0 MHz
4. Compatibility: Aplio , Xario
Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy
- 5. Probe analysis:
Connector has no dents or cracks,
No bent pins but may has scratches, .
ITT DLM-360P connector
Lock looks fine
Cable may has some stains....no cuts or tears
Probe handle and head may have scratches
Acoustic lens has a faint nick at the corner
Scan Analysis:
Air Scan: Shadows on the left
Phantom Scan: Weak elements on the left side
Body Scan: Review the Vascular scan, Right carotid has been imaged, examine the carotid lumen and color flow
Package includes :
Transducer only
- 6. Sterilized: NO
- 7. Cleaned : Yes
- 8. Extra Parts: No
- Shipping weight : 06Lbs
Stocks ID: 15766 ~ WHC9
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
- 1. Overall Condition:- As seen in images .... Good
- 2. Physical Condition: Please review images before bidding : Fair
- 3. Working Condition: Has been tested at our end, you may refer to the images for shadows and functionality..... offered AS IS
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.