ATL Access A 3.0 MHz, 3.0L ...
ATL Access A 3.0 MHz, 3.0L 12.7mm dia Ultrasound Probe P/N 101-24900-18 ~16731
Item specifics
Condition: | Used : |
---|---|
Notes: | “Strain RELIEF has a TEAR / TAPPED Image # 3, 4, 5 , 6 / Fluid leak ?” |
Brand: | ATL-UM | Color: | White |
Model: | Access A 3.0 MHZ | Size: | 12.7mm |
Product details
Vendor | ATL-UM | |
Item | ATL Access A 3.0 MHz, 3.0L 12.7mm dia Ultrasound Probe /Transducer / Scan head | |
Model/Cat# |
| 101-24900-18 |
Serial # |
| 1639 |
|
|
|
Made In: | USA | |
|
|
|
Date of manufacture |
| NA |
Short description……………….
Pre-owned item
- Frequency: 3.0 MHz
- 12.7mm dia
- 5 cm FP
- 3-8 cm FZ
- Risk class 3
- Type CF
LEMO FGG .3B Connection
Probe Applications:
- Abdominal / cardiac
Syatems:
- UltraMark 9 HDI (UM9 HDI)
UltraMark 4 (UM4)
UltraMark 9 (UM9)
UltraMark 8 (UM8)
Do not Gas sterilize
Do not use mineral oil
Non sterile
Info provided for guidance purpose only!!!
Non sterile
No manual
No case
Probe analysis:
Cable :Strain RELIEF has a TEAR / TAPPED Image # 3, 4, 5 , 6
Connector : no dents or bent pins
Lock looks good
Head and handle : some scratches on the handle , Fluid leak ?
Scan Analysis
Air Scan : Image # 2
Shipping weight : 7 pounds
Stocks ID: 16731~R3C1
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
Overall Condition:- As seen in images - As Is
Physical Condition: Kindly see all images before bidding! /Fair
Working Condition: Review Air scan Image # 1 & 2.....Not tested technically or professionally at our end/ unable to test --- being sold STRICTLY AS IS! (Exercise your judgment while buying as no returns accepted)
Biomed check is strongly recommended before use
Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.