*FREE SHIPPING* ATL L7-4 40...
*FREE SHIPPING* ATL L7-4 4000-0318-06 Linear Array Ultrasound Scan Head ~ 17636
Item specifics
Condition: | Used : |
---|---|
Notes: | “System is not included in the sale only used to show the functionality / Enjoys very good cosmetics overall ” |
Model: | L7-4 | MPN: | 4000-0318-06 |
Country/Region of Manufacture: | United States | Brand: | ATL |
Product details
Manufacturer : | ATL |
Item: | Linear Array Ultrasound Scan Head ATL L7-4 4000-0318-06 *FREE SHIPPING*
|
Model/Cat # | 4000-0318-06 |
Serial No. | 01N4YJ |
Made In: | USA |
Date of manufacture | 2006 |
Voltage : --
Short description……………….
- 1. Sale is for USED imaged item only
- 2. Signs of careful use.
- 3. Linear Array Ultrasound Scan Head ATL L7-4 4000-0318-06
7.0-4.0 MHz, Linear Array, 38 mm field of view, 128 elements
compatible with ATL UM9 HDI, HDI 1500 and HDI 3000-5000 ultrasound systems
The L7-4 probe can be utilized for vascular and small parts applications.
*** Note: Please note that provided info is for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy***
Probe Analysis:
Connector: OK, has a few scratches but no sign of broken pins refer to image 10
Cable: OK, no sign of insulation tears or cracks, refer to image 8
Head & handle: OK, with no sign of cracks or tears in the strain relief, refer to Image 7
Lock: Seems good and firm refer to image 12
Lens/Membrane: Seems good but have 2 tiny nicks on bottom edge, refer to image 9
Scan Analysis:
Air Scan: Smooth no sign of weak elements or shadow is seen refer to image 2
Phantom Scan: Smooth, refer to image 3
Body Scan: Refer to image 4-6, you can see RT carotid Lumen & blood flow
Blood flow is uniform and steady, can be seen clearly
**BUYER ENJOYS FREE DOMESTIC SHIPPING**
***Monitor is not included in the sale. We are only showing the functionality of the probe***
- 4. Package includes:-
Linear Array Ultrasound Scan Head ATL L7-4 4000-0318-06
- Sterilize : No
- Manual : No
- Cleaned : Yes
- Shipping Weight : 8 pounds
Stock ID : 17636 (WH C8)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested and working. Functionality is shown in the images for you to decide.will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.