For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

ATL C8-4V IVT Ultrasound Tr...

ATL C8-4V IVT Ultrasound Transducer Probe for ATL HDI Series Systems ~ 17645

Item specifics

Condition:Used : 
Notes:Remain unchecked at our end / Enjoys good cosmetics overall / Physical condition seems to be fair
Model:

C8 4V

MPN:

D4000-0409-04

Country/Region of Manufacture:United StatesBrand:

ATL

More details


$200.00

17645

Availability: item available

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer :

ATL

Item:


ATL C8-4V IVT Ultrasound Transducer Probe for ATL HDI Series Systems

 

Model/Cat #

C8-4V IVT

Serial No.

01TVY0

Made In: 

USA

Date of manufacture

U/K

Voltage : --

Short description……………….

  1. 1.        Sale is for USED imaged item only
  2. 2.        Signs of careful use.

       Applications: Endovaginal 

  1. 3.        ATL C8-4V Endocavity Ultrasound Probe   
  • Frequency: 4 to 8 MHz
  • FOV: 135 degrees
  • Curved array probe
  • End fire sector

     Applications: Endovaginal / OB/GYN

   Compatible Systems

   HDI 3000/3500/5000 systems

 

     

*** Note: Please note that provided info is for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy***


Probe Analysis:

 

Connector:           OK, has a minor scratch no sign of broken pins refer to image 10-11

Cable:                   OK, no sign of insulation tears or cracks, refer to image 5

Head & handle:   OK, no sign of cracks or tears in the strain relief, refer to Image 1

Lock:                     Seems good and firm refer to image 12

Lens/Membrane: Has stress effects and tear refer to the images 7-9 and decide for yourself


Scan Analysis:


We were unable to test this unit but has been removed form a hospital/working environment therefore it should work fine


 


  1. 4.        Package includes:-


 ATL C8-4V Endocavity Ultrasound Probe  


 

  1. Sterilize : No
  2. Manual : No
  3. Cleaned : Yes
  4. Shipping Weight  :  8 pounds

 

Stock ID : 17645 (WH C8)

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED

  1. 1.    Overall Condition:- As seen in images  - Good
  2. 2.    Physical Condition:  Please review images before bidding : Fair
  3. 3.    Working Condition:  Remains untested but has been pulled out of a working environment so it should work fine.will receive item as pictured ……………(offered AS IS)
  4. 4.    “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.