HP VIRIDIA 24C CRITICAL CAR...
HP VIRIDIA 24C CRITICAL CARE MONITOR (NBP/EKG/SpO2/CO/TEMP/PRINT) W/ LEADS~14552
Item specifics
Product details
Manufacturer: | Philips / HP / Agilent Technologies | |
Item: | HP VIRIDIA 24C CRITICAL CARE MONITOR (NBP/EKG/SpO2/CO/TEMP/PRINT) W/ LEADS | |
Model/Cat # |
| M1205A / M1204A |
Serial No. |
| 4006A74847 |
Made In: | USA / Germany | |
Date of manufacture |
| 07- 2000 |
Short description……………….
Pre-owned items
SALE is for patient care monitor with accessories
- 1. Sale is for imaged items only
- Item may have scratches/scuffs, residual adhesive, minor dust, minor observable wear, in general enjoys good cosmetics
- 3. Package includes the following
Monitor
- HP P/N M1205-83000 (M1205A/M1204A) monitor, SN 4006A74847 DOM:2000-7
Comments:
TOUCH SCREEN: No
Monitor screen Scratches: No
Crack in the case: No
Handle : INTACT
Options: H07 B.0 : Standard (ECG NBP SpO2 Temp, Print) , M1235A DTM, M1012A CO are installed.
Blood Analysis (BAM M1022A), & M1016A CO2 ARE NOT INSTALLED
ADULT / Pediatric / Neonatal settings
RACK
- HP-Agilent Philips M10141A Module Rack, SN: 3805A35726
MODULES
- Agilent HP M1002B ECG/Resp Module
d. Agilent HP M1008B NBP Module
f. Agilent HP M1020A SpO2/Pleth Module
g. HP M1012A CO module
h. HP Agilent M1029A Temprature Module
i. HP Agilent M1116B Printer recorder module .............TOP COVER IS MISSING
LEADS & CABLES
j. NBP Hose (No cuff) .... NEW
k. Spo2 Cable with sensor .... New
l. ECG Cable with leads .....New
m. Madison Corp Rack to monitor interface cable .......Used
n. Power cord...........NEW
- 4. Following are not included:
- a. HP M1180A PAN MAX Mobile stand: Not included
- b. HP Rack pole: NOT included
- c. Optional item: SaniBasket for sanitation wipes
5. Manual: No
6. Sterilized: No
7. Cleaned: Yes
8. Shipping weight: 40 pounds
9. Shipping Ready: yes
Stocks ID: 14552 / WHP |
|
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition:
1. Overall Condition: - As seen in images – Good
2. Physical Condition: Please review images before bidding – Good
3. Working Condition: Powers on, following all commands, SpO2, EKG and NBP parameters checked and seems to be working well. CO / TEMP / Printer modules are not tested .....---- offered AS IS
4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)