MPN- 862135
Product details
Manufacturer | Philips Healthcare |
Item: | Philips Intellivue MP30 Anesthesia Patient Monitor With Module & Leads |
Model/Cat # | MP30 / M8002A / Ref 862135 |
Serial No. | DE72873916 |
Made In: | Germany |
Date of Manufacture: | 2010-02 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description...
- Sale includes imaged items only.
- Condition: Signs of moderate use.
- Functionality: Tested and shown to be in good working condition, as demonstrated in the images.
Key Details:
- Battery Status: Not installed.
- Parameters: NBP, SpO2 (Nellcor Oximax), ECG.
- Monitor Options: H30, A04, C01, C02, C15, C20.
- Module: Philips M3001A MMS patient monitoring module (Ref 862442 | SN# DE717M1771 | DOM: 2008-09 | Opt: A01C06).
- No dents or cracks; softpads intact.
- Monitor Software Revision: L.01.06.
- Other Modules: None included.
- Printer: Installed.
- LCD Display: Responsive touchscreen; may have a few scratches and appears dull.
- Profile Settings: Adjustable.
- Handle & Trim Knob: Both are intact and functional.
- Softpads: Working.
- Physical Condition: No dents or cracks noted; minor scratches or scuffs possible.
- Date & Time: Date is correct, and time can be adjusted per the time zone.
Included Accessories:
- Patient Leads: A mix of new and used:
- Reusable SpO2 Sensor (Ref SP9325E | Type Nellcor Oximax with extension cable).
- SG5124S ECG Cable with 5 leads (New).
- SG5124S NBP Hose (Used).
- SC2711-11 Adult Cuffs (New).
Additional Information:
- Disposables/Consumables: Not included.
- Power Cord: Included.
- Stand: Not included.
- Manual: Not included.
Please review images and check for compatibility before bidding.
Package Includes:
- Philips Intellivue MP30 Anesthesia Patient Monitor.
- Philips M3001A MMS Module (Ref 862442 | SN# DE717M1771).
- Reusable SpO2 Sensor (Ref SP9325E | Type Nellcor Oximax with Extension Cable).
- SG5124S ECG Cable with 5 Leads (New).
- SG5124S NBP Hose (Used).
- SC2711-11 Adult Cuffs (New).
- Power Cord.
Items shown in photos are the exact items that will ship. If it is not shown in the photos, it is not included.
- Sterilized: No.
- Manual: No.
- Cleaned: Yes.
- Shipping Weight: 30 lbs.
Stock ID : 35318 (P.O 4014) (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images....will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)