For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2004 PHILIPS V24C CRITICAL ...

2004 PHILIPS V24C CRITICAL CARDIAC CARE TOUCH SCREEN MONITOR W/ NEW LEADS~14530

Item specifics

Condition:Used : 
Notes:Enjoys very good cosmetics / NBP, SpO2, EKG , CO, TEMP & Printer modules with NBP ECG SpO2 Cables. See Images for cosmetics / READ details for OPTIONS
Model Year:2004Model:

V24c

Type:ScreenMPN:

M1205-83000

More details


$476.00

14530

Availability: This product is no longer in stock.

Product details

Manufacturer:

 

Philips / HP / Agilent Technologies

Item:

 

HP/Philips V24C Patient Monitor W/ Rack Six Modules 05 Cables  

Model/Cat #

 

 M1205A / M1204A

Serial No.

 

See below

Made In:

 

USA / Germany

Date of manufacture

 

See Below

Short description……………….

Pre-owned items         

SALE is for patient care monitor with accessories

  1. 1.              Sale is for imaged items only
  2. Item may have scratches/scuffs, residual adhesive, minor dust, minor observable wear, in general enjoys good cosmetics 
  3. 3.              Package includes the following

Monitor

  1. HP P/N M1205-83000 (M1205A/M1204A) monitor, SN 4335A23958 DOM:10-2004 

Comments:

TOUCH SCREEN: Yes

Monitor screen Scratches: No

Crack in the case: No

Options: H07 D.0: Standard (ECG NBP SpO2 Temp, Print) M1235A DTM and M1012A CO, M1016A CO2 are installed. 

 Blood Analysis (BAM M1022A) is not installed!

ADULT / Pediatric / Neonatal settings 

RACK

  1. HP-Agilent Philips M10141A Module rack, SN: DE320C2967 DOM 07/2004 (no pole clamp)

MODULES

  1.  Agilent HP M1002B ECG/Resp Module 

d. Agilent HP M1008B NBP Module 

f. Agilent HP M1020A SpO2/Pleth Module 

g.  HP M1012A CO module 

h.  HP Agilent  M1029A Temperature module 

i.  HP Agilent M1116B Printer recorder module 

LEADS & CABLES

j.     NBP Hose (No cuff) .... NEW

k. Spo2 Cable with sensor .... new 

l. ECG Cable with leads .....New 

m.  Madison Corp Rack to monitor interface cable 

 n. Power cord

  1. 4.            Following are not included:
  2. a.    HP M1180A PAN MAX Mobile stand: Not included 
  3. b.   HP Rack pole: NOT included 
  4. c.     Optional item: SaniBasket for sanitation wipes

5.   Manual: No

6.   Sterilized: No

7.   Cleaned: Yes

8.  Shipping weight: 40 pounds

9.  Shipping Ready: yes

 

Stocks ID:  14530 / WHP

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

1.  Overall Condition: - As seen in images –  Very Good

2.  Physical Condition:  Please review images before bidding – Very Good 

3.  Working Condition:  Powers on, following all commands, SpO2, EKG and NBP parameters checked, Printer is working,  other parameters are not tested .....---- offered AS IS

4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”

5.  Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)

6.  Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.